título: Correlação entre quantidade de glicose sanguínea informada por equipamento eletrônico e sinal bioelétrico detectado por Arduino: um estudo piloto

Title: Correlation between the amount of blood glucose reported by electronic equipment and the bioelectric signal detected by Arduino: a pilot study

AUTOR(s): Nogueira, H.S.

RESUMO: O automonitoramento de glicemia é possível graças ao uso de equipamentos eletrônicos portáteis, que utilizam tiras reagentes. O objetivo deste estudo foi verificar a correlação entre o valor de glicemia informado por um eletrônico deste tipo, com a derivada e a integral de sinal bioelétrico. Para tanto foi desenvolvido um sistema de aquisição de dados que envolveu placa com microcontrolador da empresa Arduino e o software Parallax Data Acquisition (PLX-DAQ) da empresa Parallax Inc, o que permitiu transferir os dados obtidos para planilha do Excel. Com isso, foi realizada análise matemática (derivada e integral) dos sinais, e correlação destes parâmetros com o valor de glicemia informado pelo equipamento eletrônico. Os resultados apresentaram uma correlação média entre a integral/derivada dos sinais e os valores de glicemia. Com isso, conclui-se que é possível realizar as inferências propostas com uso do Arduino, mas que para que haja maior confiabilidade, é necessário que estudos futuros sejam realizados com amostras de tamanho maior, com faixa de valores de glicemia maior. 

ABSTRACT: Self-monitoring of blood glucose is possible thanks to the use of portable electronic devices, which use reagent strips. The objective of this study was to verify the correlation between the blood glucose value reported by an electronic device of this type, with the derivative and the integral of the bioelectric signal. For this, a data acquisition system was developed, which involved a microcontroller board from the company Arduino and the software Parallax Data Acquisition (PLX-DAQ) from Parallax Inc. With this, a mathematical analysis (derivative and integral) of the signals was performed, and correlation of these parameters with the blood glucose value informed by the electronic equipment. The results showed an average correlation between the integral/derivative of the signals and the blood glucose values. Thus, it is concluded that it is possible to perform the proposed inferences with the use of Arduino, but for greater reliability, it is necessary that future studies are performed with larger sample sizes, with a wider range of blood glucose values. 

PALAVRAS-CHAVE: engenharia biomédica; biomateriais; diabetes.

KEYWORDS: biomedical engineering; biomaterials; diabetes.

CITAÇÃO / CITATION: Nogueira, H. S. Correlação entre quantidade de glicose sanguínea informada por equipamento eletrônico e sinal bioelétrico detectado por Arduino: um estudo piloto. The Academic Society Journal, 5(3) 138-162, 2021. DOI: doi.org/10.32640/tasj.2021.3.138.